I.Equipment Name and Model:SLF6305-0302 Drying Oven
II. Technical Specifications and Basic Configuration:
The equipment is primarily used for the hot air drying process of precision ceramic substrates. The specific details are as follows:
2.1 Rated Temperature: 150°C; Maximum Temperature: 250°C
2.2 Effective Height: 50mm
2.3 Belt Width: 635mm
2.4 Belt Material: SUS304
2.5 Maximum Load: 20Kg/m² (excluding belt weight)
2.6 Drive System: Large Wrap Angle Friction Drive
2.7 Speed Range: 20~160mm/min, Inverter Stepless Speed Control
2.8 Heating Element: Alloy Heating Wire
2.9 Furnace Structure: Made of full stainless steel, high cleanliness inside the furnace
2.10 Heating Method: Hot air motor heating from the top, horizontal air supply, adjustable wind speed
2.11 Sintering Environment: Air
2.12 Exhaust System: One set of exhaust chimneys at both the inlet and outlet
2.13 Cooling Method: Air Cooling
2.14 Structural Division: (Refer to Section 3.1 for technical details)
2.15 Temperature Control Accuracy: ±1°C
2.16 Furnace Temperature Uniformity: ±5°C (in the constant temperature zone)
2.17 Number of Temperature Zones: 3
2.18 Number of Temperature Control Points: 3
2.19 Thermocouple: K Type
2.20 Heating Rate: ≤10°C/min
2.21 Surface Temperature Rise: <35°C
2.22 Heating Power: 9kW
2.23 Standby Power Consumption: ≤3kW
2.24 Weight: Approximately 400Kg
2.25 Dimensions: 3200mm×1100mm×1350mm (L×W×H), excluding (feet, chimneys, indicator lights)
2.26 The equipment is equipped with four casters for easy mobility.
Table 1: Delivery Summary | |||
Category | Description | Qty | |
Basic Components | Kiln Main Unit | 1 set | |
Inspection Certificate | Certificates of conformance for major external components | 1 set | |
Technical documents | User Manual & Technical Documents for Major Purchased Components | 1 set | |
Key Component | Heating Wire | 1 set | |
Hot Air Motor | 1 set | ||
Spare Parts | Solid State Relay (SSR) | 1 unit | |
Heating Wire | 1 set |
III. Normal Operating Conditions for the Equipment
3.1 Environmental Conditions: Temperature: 0~40°C, Humidity: ≤80% RH, no corrosive gases, no strong air flow disturbances.
3.2 Ventilation System: Non-contact connection to the user's exhaust system, exhaust capacity greater than 20m³/h.
3.3 Floor: Level, no significant vibration, load-bearing capacity >500Kg/m².
3.4 Power Conditions: Capacity greater than 12KVA, 3-phase 5-wire, voltage 220/380V, frequency 50Hz (as per national standards). Live wires: Yellow, Green, Red; Neutral wire: Blue; Ground wire: Yellow-Green. This power line is dedicated; please use a separate power distribution system. Precision instrument power supplies and high-power equipment such as welding machines, electric furnaces, and metal cutting machines should not be connected to this power distribution system.